Sintesi delle specifiche
-
Measured variables
Transmittance, opacity, relative opacity, extinction, dust concentration
-
Process temperature
–40 °C ... +600 °C
-
Measuring range
Transmittance: 100 ... 80 % / 100 ... 0 %
Opacity: 0 ... 20 % / 0 ... 100 %
Relative opacity: 0 ... 20 % / 0 ... 100 %
Extinction: 0 ... 0.1 / 0 ... 2
Dust concentration: 0 ... 200 mg/m³ / 0 ... 10,000 mg/m³
The measurement depends on measuring distance and dust properties
Campo applicativo
The DUSTHUNTER T100 is a measuring device for dust at medium to high concentrations. Basic measuring value is transmittance. Opacity and extinction can be calculated and displayed as well as the dust concentration after gravimetric calibration. The device has an integrated contamination check. The DUSTHUNTER T100 is approved according to EN 15267.
Emissions monitoring at power plants and waste incineration plants
Monitoring of filter systems
Monitoring of dust load in factory halls
Control of fresh air and exhaust air units
Device properties:
For medium to high dust concentrations
On-board contamination check
Automated thorough check of zero and reference point
For small to large measuring distances
Vantaggi
Easy installation, commissioning and operation
Measurement independent of gas velocity, humidity and particle charge
Low maintenance due to self-monitoring
Approved according to EN 15267
Selezione Xpert
-
Prodotti speciali
- Progettati per applicazioni complesse
Eccellenza tecnica
Semplicità
Variabile
-
Prodotti semplici
- Selezione, installazione e messa in funzione semplice
Eccellenza tecnica
Semplicità
-
Prodotti standard
- Affidabilità, solidità e manutenzione ridotta
Eccellenza tecnica
Semplicità
-
Prodotti di fascia alta
- Funzionalità e convenienza elevate
Eccellenza tecnica
Semplicità
-
Prodotti speciali
- Progettati per applicazioni complesse
Eccellenza tecnica
Semplicità
Variabile
Selezioni FLEX | Eccellenza tecnica | Semplicità |
---|---|---|
Selezione Fundamental Soddisfa le tue esigenze di misurazione di base |
Eccellenza tecnica
|
Semplicità
|
Selezione Lean Gestisci agevolmente i tuoi processi core |
Eccellenza tecnica
|
Semplicità
|
Selezione Extended Ottimizza i tuoi processi con tecnologie innovative |
Eccellenza tecnica
|
Semplicità
|
Selezione Xpert Controlla le tue applicazioni più impegnative |
Eccellenza tecnica
|
Semplicità
Variabile |
-
-
Manuale operativo (BA)
DUSTHUNTER T
Dust Concentration Monitor
EN IT 01/01/2025Lingua:
Inglese
Versione:
01/01/2025
Dimensione del file:
7.2 MB
Nome del file:
8029847_YWL2_OI_DUSTHUNTER_T_en_V3-0_2016-08_EHS.pdf
-
-
-
Brochure di competenza (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
Best in class dust measurement technology with the scattered light and
transmittance dust measuring devices from Endress+HauserLingua:
Inglese
Versione:
01/01/2025
Dimensione del file:
3 MB
Nome del file:
8030014_CP_Dust_Measuring_Devices_en_V3-0_2025.01.pdf
-
-
-
Brochure di competenza (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceLingua:
Inglese
Versione:
01/01/2025
Dimensione del file:
4.5 MB
Nome del file:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Verifica DTM
DUSTHUNTER T100 SDD file
SOPAS device description file for DUSTHUNTER T100
Lingua:
Language neutral
Versione:
05/12/2024
Dimensione del file:
616 KB
Nome del file:
DUSTHUNTER T100 SDD file
-