Données clés
-
Measured variables
Visibility (K-value), NO, NO2, NOx, CO, Temperature
-
Measuring range
K-value: 0 ... 15 km⁻¹ / 0 ... 200 km⁻¹
NO: 0 ... 20 ppm / 0 ... 45 ppm
NO2: 0 ... 1 ppm / 0 ... 5 ppm
CO: 0 ... 100 ppm / 0 ... 300 ppm
Temperature: -25 ... +55 °C / -25 ... +75 °C -
Conformities
ASTRA "Guideline - Ventilation of Road Tunnels" (2008)
RABT 2006
RVS 09.02.22
Domaine d'application
The VICOTEC320 measures very small concentrations of NO2 and NO as well as the visibility and temperature in road tunnels quickly and simultaneously. And all this using industry-proven components – without test gases for zero and reference point. An automated, cyclic adjustment of zero and reference point ensures exact values. The rugged housing even withstands thorough tunnel washing operations without any impairments.
Ventilation control and filter monitoring in tunnels
Monitoring of air quality in road tunnels
Device properties:
Very low detection limits for NO and NO2
Automatic function monitoring and self-adjustment
Very rugged design in stainless steel
Automatic beam alignment between sender/receiver unit and reflector
Avantages
Energy and cost savings for ventilation control due to very low zero offset and accurate measurement
Low operational costs because no air aspiration of ambient air and no test gases are required
Low maintenance requirements due to long maintenance interval (approx. 1 year)
Xpert selection
-
Produits spécialisés
- Conçu pour les applications exigeantes
Excellence technique
Simplicité
Variable
-
Produits simples
- Facile à sélectionner, à installer et à utiliser
Excellence technique
Simplicité
-
Produits standard
- Fiable, robuste et effort de maintenance réduit
Excellence technique
Simplicité
-
Produits haut de gamme
- Hautement fonctionnel et pratique
Excellence technique
Simplicité
-
Produits spécialisés
- Conçu pour les applications exigeantes
Excellence technique
Simplicité
Variable
FLEX selections | Excellence technique | Simplicité |
---|---|---|
Fundamental selection Parfait pour les applications de base |
Excellence technique
|
Simplicité
|
Lean selection Performances optimales pour piloter les applications standards |
Excellence technique
|
Simplicité
|
Extended selection Fonctionnalités avancées pour maximiser vos process |
Excellence technique
|
Simplicité
|
Xpert selection Performances exceptionnelles pour applications exigeantes |
Excellence technique
|
Simplicité
Variable |
-
-
Brochure Compétence (CP)
Traffic and Tunnel Safety Solutions
An overview brochure about traffic and tunnel sensor, their
development during the last 60 years, the main applications in front
and within a tunnel as well as the measuring devices at a glanceLangue:
Anglais
Version:
01/01/2025
Taille du fichier:
4.2 MB
Nom du fichier:
8029977_CP_Traffic_Sensors_en_V2-0_2025.01_EHS.pdf
-
-
-
Brochure Compétence (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceLangue:
Anglais
Version:
01/01/2025
Taille du fichier:
4.5 MB
Nom du fichier:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Innovation (IN)
VICOTEC320 – Air quality tunnel sensors to control ventilation in road tunnels
The VICOTEC320 measures very small concentrations of NO2 and NO as well as the visibility and temperature in road tunnels
simultaneously and fast.Langue:
Anglais
Version:
01/01/2025
Taille du fichier:
2.6 MB
Nom du fichier:
8030070_IN_VICOTEC320_en_V4-0_2025.01_EHS.pdf
-
-
-
DTM de vérification
VICOTEC320 SDD file
SOPAS device description file for VICOTEC320
Langue:
Language neutral
Version:
19/10/2015
Taille du fichier:
382 KB
Nom du fichier:
VICOTEC320 SDD file
-