Specs at a glance
-
Process temperature
-20°C...+80°C
(-4°F...+176°F)
Field of application
The Nivector FTI26 is a cost-efficient point level switch for solids in the food industry and powder applications in all industries. The capacitance device convinces with the best build-up performance in class and a high sensitivity. All industry compliant certificates are available. In addition, the FTI26 is industry 4.0 ready with IO-Link communication.
For MIN or MAX detection in silos with powdered and fine-grained solids, like plastic granules, grain, sugar, spices, coffee powder, laundry detergent
Process connections: G1" thread, Tri-Clamp 2" via adapter
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +86psi)
International explosion protection certificates (Dust Ex), hygienic certificates
Benefits
-
Easy installation even in tight conditions or where access is restricted thanks to the compact design
Fulfillment of all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); cleanable (IP69)
IO-Link reduces costs and complexity with an easy configuration of the devices via engineering tools
Best build-up performance in class and high sensitivity
No individual adjustment to each medium necessary
LED signalization for on-site function check
Videos
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Operating Instruction (BA)
Nivector FTI26 Operating Instructions
English version - 10/2019
Point level switch for powdered and fine-grained solids; IO-Link
EN 01/10/201918/01/201916/07/201810/07/2018Language:
English
Version:
01/10/2019
File size:
1.6 MB
File name:
BA01830FEN_0419.pdf
-
-
-
Application software
Powerful IO-Link Function Block Library for the Siemens TIA Portal
English version - 08/2023
Thanks to the newly available free software library, all IO-Link capable measuring devices from Endress+Hauser can now be integrated into a Siemens TIA Portal environment much more easily and significantly faster than ever before. The streamlined process of device integration not only brings drastic time savings, but the user can now get by without any programming knowledge at all.
Language:
English
Version:
22/08/2023
File size:
3.4 MB
File name:
IO_Link_Siemens_Library_V1.3.zip
-
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN 25/03/202415/09/202328/10/202130/07/202119/06/2020Language:
English
Version:
25/03/2024
File size:
1.1 MB
File name:
TI00426FEN_2524.pdf
-
-
-
Technical Information (TI)
Nivector FTI26 Technical Information
Point level switch for powdered andfine-grained solids
EN 01/10/201926/01/2018Language:
English
Version:
01/10/2019
File size:
801.5 KB
File name:
TI01384FEN_0219.pdf
-
-
-
Operating Instruction (BA)
Nivector FTI26 Operating Instructions
Point level switch for powdered and fine-grained solids; IO-Link
EN 01/10/201918/01/201916/07/201810/07/2018Language:
English
Version:
01/10/2019
File size:
1.6 MB
File name:
BA01830FEN_0419.pdf
-
-
-
Operating Instruction (BA)
Nivector FTI26 Operating Instructions
Nivector FTI26; Point level switchfor powdered and fine-grained solids
EN 01/10/201911/01/201916/02/2018Language:
English
Version:
01/10/2019
File size:
1.5 MB
File name:
BA01832FEN_0319.pdf
-
-
-
Short Instruction (KA)
KA Nivector FTI26
Capacitance
EN 16/09/2022Language:
English
Version:
16/09/2022
File size:
383.4 KB
File name:
KA01627FEN_0122-00.pdf
-
-
-
Short Instruction (KA)
Nivector FTI26 Brief Operating Instructions
Nivector FTI26; Point level switch for powdered and fine-grained solids
EN 01/10/201916/07/2018Language:
English
Version:
01/10/2019
File size:
1.5 MB
File name:
KA01408FEN_0219.pdf
-
-
-
Short Instruction (KA)
KA Nivector FTI26 IO-Link
Capacitance
EN 15/09/2022Language:
English
Version:
15/09/2022
File size:
367.1 KB
File name:
KA01617FEN_0122-00.pdf
-
-
-
Ex Safety Instruction (XA)
Nivector FTI26 Control Drawing Safety Instructions
Capacitive Level Measurement
EN 28/01/2019Language:
English
Version:
28/01/2019
File size:
271 KB
File name:
XA01821FEN_0119.pdf
-
-
-
Ex Safety Instruction (XA)
Nivector FTI26
ATEX:
II 1/3 D Ex ta/tc IIIC T100°C Da/Dc
IECEx:
Ex ta/tc IIIC T100°C Da/DcEN 07/09/202023/07/2018Language:
English
Version:
07/09/2020
File size:
1.2 MB
File name:
XA01734FEN_0220.pdf
-
-
-
Ex Safety Instruction (XA)
Nivector FTI26
Ex ta IIIC T100°C Da
Ex tc IIIC T100°C Dc XEN 23/12/2019Language:
English
Version:
23/12/2019
File size:
260.8 KB
File name:
XA01943FEN_0119.pdf
-