©Endress+Hauser
Successor
Basic model for level liquid applications
Read more
Economically efficient basis model for level measurement in solids
Read more
More simplicity for your application
Discover more.
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Characteristic / Application
Characteristic / Application
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
Ambient temperature
-40 °C...+80 °C (-40 °F...+176 °F)
Process temperature
-40 °C...+130 °C (-40 °F...+266 °F)
Process pressure / max. overpressure limit
Vacuum...3 bar (Vacuum...43.5 psi)
Process connection
Thread: NPT 1 1/2, G 1 1/2 Slip on flange: DN80...DN150 (3"...6"),
Max. measurement distance
Max. measurement distance
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX, FM, CSA, IECEx, TIIS, NEPSI Overfill prevention WHG SIL Marine GL/ABS/NK
Characteristic / Application
Non-contact level measurement in powdery to granular bulk solids up to 15m measurering range. Applications with highly abrasive bulk solids e.g. ferrite / glas ...
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
Accuracy
+/- 15 mm (or 0.04% of range, whatever is larger)
Ambient temperature
-40 °C...+80 °C (-40 °F...+266 °F)
Process temperature
-40 °C...+80 °C (-40 °F...+266 °F)
Process pressure / max. overpressure limit
Vacuum... 3bar (Vaccum... 43.5 psi)
Max. measurement distance
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certificates / Approvals
ATEX, FM, CSA, IECEx, TIIS, NEPSI
Options
Separate display Mounting bracket variable flange seal for adjustment
Most downloaded
Micropilot M FMR244
PROFIBUS PA
Operating Instructions
English version - 06/2011
Continuous and non-contact level measurement.
Cost-effective 4 to 20mA 2-wire technology.
Suitable for hazardous locations.
EN
DE FR
More
28/06/2011
30/07/2010
02/05/2008
28/02/2007
31/08/2006
Language:
English
Version:
28/06/2011
File size:
2.9 MB
File name:
BA00249FEN_1311.pdf
120 documents
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245
Technical Information
Continuous and non-contact level measurement. Cost-effective 4 to 20 mA 2-wire technology. Suitable for hazardous locations.
EN
German French Italian Japanese Polish Russian Chinese
Select other language
01/10/2012
28/06/2011
31/01/2011
30/07/2010
17/12/2009
Language:
English
Version:
01/10/2012
File size:
4.4 MB
File name:
TI00345FEN_1512.pdf
Micropilot M FMR230, 231
HART, PROFIBUS PA, FOUNDATION
Fieldbus
Description of Instrument Functions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
Czech German Spanish French Italian Japanese Polish Russian
Select other language
30/07/2010
03/08/2006
31/12/2005
22/12/2003
24/03/2003
Language:
English
Version:
30/07/2010
File size:
1.7 MB
File name:
BA221FEN_0310.pdf
Micropilot M FMR244
FOUNDATION Fieldbus
Operating
Instructions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
German
Select other language
28/06/2011
30/07/2010
02/05/2008
30/06/2007
31/05/2006
Language:
English
Version:
28/06/2011
File size:
3.6 MB
File name:
BA00250FEN_1311.pdf
Micropilot M FMR244
PROFIBUS PA
Operating Instructions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
German French
Select other language
28/06/2011
30/07/2010
02/05/2008
28/02/2007
31/08/2006
Language:
English
Version:
28/06/2011
File size:
2.9 MB
File name:
BA00249FEN_1311.pdf
Micropilot M FMR240, 244, 245, 250
HART, PROFIBUS PA,
FOUNDATION Fieldbus
Description of Instrument Functions
Continuous and con-contact level measurement. Cost-effective 4 to 20 mA 2-wíre technology. Suitable for hazardous locations.
EN
German Spanish French Italian Japanese Polish Portuguese Russian
Select other language
03/08/2006
31/01/2006
21/11/2005
01/08/2004
Language:
English
Version:
03/08/2006
File size:
1.8 MB
File name:
BA291FEN.pdf
Microilot M FMR244
HART
Operating Instructions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
Czech German French Italian Japanese Polish Russian
Select other language
28/06/2011
30/07/2010
02/05/2008
28/02/2007
31/08/2006
Language:
English
Version:
28/06/2011
File size:
2.7 MB
File name:
BA00248FEN_1311.pdf
Micropilot II/M - exchange of housing F12
Micropilot II/M - exchange of housing F12
EN
German
Select other language
15/04/2021
Language:
English
Version:
15/04/2021
File size:
194.9 KB
File name:
KA00556F00_A2.pdf
Micropilot M FMR244
Brief Operating Instructions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
German French Chinese
Select other language
31/12/2009
Language:
English
Version:
31/12/2009
File size:
1 MB
File name:
KA1011FEN_1209.pdf
Micropilot M FMR244
Brief Operating Instructions
Continuous and non-contact level measurement. Cost-effective 4 to 20mA 2-wire technology. Suitable for hazardous locations.
EN
German French Chinese
Select other language
31/12/2009
Language:
English
Version:
31/12/2009
File size:
1 MB
File name:
KA1010FEN_1209.pdf
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
EN
German Spanish French Italian Dutch
Select other language
27/06/2007
31/05/2007
Language:
English
Version:
27/06/2007
File size:
235.5 KB
File name:
KA137Fa6_0607.pdf
Search spare parts by number in drawing
36 spare parts & accessories
36 spare parts
36 accessories
Cover F12/T12 Alu, coated, gasket
Drawing number
Order code
20
517391-0011
Cover F12/T12 Alu, window, gasket
Drawing number
Order code
20
52005936
Set of screws housing F12/T12/F23
Drawing number
Order code
12
535720-9020
Cover T3/T12 Alu, coated, gasket
Drawing number
Order code
25
518710-0020
Drawing number
Order code
11
52005643
Cover terminal compartment F12/F23
Drawing number
Order code
11
52006026
Cover terminal compartment F12/F23,FHX40
Drawing number
Order code
11
52019062
O-ring 113.9x3.63 EPDM, 5 pieces
Terminal module 4-pole, HART, 2-wire
Drawing number
Order code
35
52006197
Terminal module 4-pole, PA, FF
Drawing number
Order code
35
52012156
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Drawing number
Order code
35
52013302
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
Drawing number
Order code
35
52013303
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
Drawing number
Order code
35
52018949
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
Drawing number
Order code
35
52018950
Drawing number
Order code
40
52026443
Adapter cable FMR2xx/53x, FMU4x, FMP4x
Tool for unplugging the antenna cable
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
Modification name plate, non Ex
Adaption kit housing F12, 2-wire, FHX40
Protective cover for housing T12/F12, SS
Seal, adjustable, ASME 3"/ JIS 80A
Seal, adjustable, ASME 4"
Seal, adjustable, ASME 6"/ JIS 150A
Mounting bracket FHX40 1" / 2" pipe
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all